Measured data, test report references and installation logic for the RS100 polyolefin coil saddle system. Written for engineers, buyers and QA teams who need to verify a supplier before ordering.

Each item below is traceable to a report number or test record, not a marketing claim.

Tensile 22.0 MPa (ASTM D638), Shore D 69 (ASTM D2240), compressive 44.4 MPa at 50% strain (ASTM D695). Specimen results, not a rated capacity.
Read the data →
Stepwise static compression, 60 minutes per level: no abnormality from 10 t to 45 t, slight indentation at 50 t and 60 t. Rail insert exceeded 168 kN.
See test table →
REACH SVHC screening: PASS, 253 substances, all at or below 0.1% w/w. RoHS: PASS against 2011/65/EU as amended by (EU) 2015/863.
Report details →Steel mills, coil trader warehouses, processing lines, non-ferrous coils, ports and machinery manufacturing coil stores.
Ask for the full report set before you place an order. Each reference can be verified with the issuing body.
| Document | Reference | Issued by / scope |
|---|---|---|
| Material property test | A2260880383101 | CTI, 14-23 October 2026, submitted sample |
| RoHS test | A2260880951101001 | CTI, 10-15 October 2026 |
| REACH SVHC screening | A2260880951102001 | CTI, 10-30 October 2026, 253 substances |
| Internal load verification | ZWH-2025-010 | Manufacturer test record, Jan 2024 - Jan 2025 |
The internal load record is a manufacturer document, not a third-party accredited certificate. Multi-tier storage requires project-specific engineering review.
Commercial enquiry — full product range, pricing, lead time and export terms are handled on our export site 99racking.com.
Technical question — send coil weight, outside diameter, width, number of positions and floor conditions; we will return a layout proposal.
+86 180 6796 5756